BEVITAL AS

Targeted Metabolomics Services

Vitamin B2

B2
Updated 21/12/2022

What is measured?

Synonym: Riboflavin.
What is measured: Riboflavin and the flavin cofactor, flavin mononucleotide (FMN).
Method(s): LC-MS/MS (1).

Indication(s)

Riboflavin is a marker of vitamin B2 status (2).

Specimen, collection and processing

Patient/subject: Prandial status may have some effect on concentrations of riboflavin, but has no effect on FMN.
Matrix: Riboflavin and FMN are most stable in EDTA plasma.
Volume: Minimum volume is 60 µL, but 200 µL is optimal and allows reanalysis.
Preparation and stability: The plasma fraction must be separated from the blood cells, preferentially within 30 minutes. Samples should be put on ice, and protected from light. Riboflavin is light sensitive. In serum, citrate plasma or heparin plasma, FMN is converted to riboflavin. Measurement of the sum of riboflavin plus FMN is an option in samples that have not been adequately treated.

Transportation

Frozen, on dry ice. (for general instruction on transportation, click here.)

Reported values, interpretation

Reported values (riboflavin/FMN): 5-100/3-30 nmol/L.
Intraclass correlation coefficient (ICC) (riboflavin/FMN): 0.79 /0.69.

Literature

1. Midttun, O., Hustad, S., and Ueland, P.M. (2009). Quantitative profiling of biomarkers related to B-vitamin status, tryptophan metabolism and inflammation in human plasma by liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Sp 23, 1371-79.
2. Hustad, S., McKinley, M.C., McNulty, H., Schneede, J., Strain, J.J., Scott, J.M., and Ueland, P.M. (2002). Riboflavin, flavin mononucleotide, and flavin adenine dinucleotide in human plasma and erythrocytes at baseline and after low-dose riboflavin supplementation. Clin Chem 48, 1571-77.

Scroll to Top

Olink Proteomics

Please fill out the fields below (*required).
We will respond to you ASAP.
Thank you!

Customized analyses

Please fill out the fields below (*required).
We will reply to you soon for a detailed project discussion.
Thank you for reaching out to Bevital!

Mix-and-Match

Please fill out the fields below (*required).
We will respond to you as soon as possible.
Thank you for reaching out to Bevital!

Ready-to-Run

Please fill out the fields below (*required).
We will respond ASAP.
Thank you!

Thanks for joining!

Get updates about new method developments, publications and comming events.